Power
station type and history |
 |
|
Number of
Units: |
2 steam turbines + 2 boilers |
|
Location: |
Europe |
|
Year
Commissioned: |
1974/75 |
|
Service
Hours: |
Never
operated commercially |
|
Condition:
|
Never
used commercially |
|
Status:
|
Installed on
foundations within
Power Station building
|
|
Two steam turbines |
 |
|
Number of
Units: |
Two |
|
Manufacturer: |
BBC-Brown Boveri |
|
Type: |
1974/75 |
|
Rated Power: |
50,000 KVA @ 0.8 P.F.
(40MW) |
|
Speed:
|
3000 RPM |
|
Inlet Pressure: |
31 barg |
|
Inlet Temperature: |
400oC |
|
Inlet Flow @ MCR: |
180t/h |
|
Inlet Pressure: |
31 barg |
|
Condenser: |
Seawater Cooled |
|
Two
alternators |
 |
|
Number of
Units: |
Two |
|
Manufacturer: |
BBC |
|
Capacity: |
50,000 kVA |
|
Power Factor: |
0.80 |
|
Active Power: |
40,000kW |
|
Rated Voltage: |
10.5kV |
|
Frequency: |
50HZ |
|
Speed: |
3000RPM |
|
Two
boilers |

|
|
Number: |
Two |
|
Manufacturer: |
Sulzer |
|
Fuel: |
HFO or mixed Blast Furnace Gas / HFO |
|
Steam Conditions: |
Design Pressure
39.2 Barg |
|
Pressure at Super Heater Outlet 31.4 Barg |
|
Temperature at Super Heater Outlet
410 oC |
| Output: |
Flow at MCR with 100% HFO
or 80% BFG and 20% HFO |
| Efficiency: |
100% HFO at MCR
92% |
|
80% BFG / 20% HFO at MCR
86.5% |
Balance of plant
BOP available to purchase
Documentation
Operation and Maintenance Manuals available
Drawings available for most equipment, including drawing register
Contact Us
If you have a possible application for this plant, please
contact us
|